Valve overview:
Cryogenic globe valves are mainly used in low-temperature medium pipeline systems, with the characteristics of flexible switching and reliable sealing
Executive standard:
Design standard: GB/T24925-2019
Normal temperature sealing performance: GB/T26180-2011
Low-temperature sealing performance: GB/T24925-2019
Installation and maintenance matters:
When installing the valve, it should be noted that the flow direction of the valve mark should be consistent with the flow direction of the medium
Make sure the pipes are blown clean before installation
The valve should be in the open state when connecting
After the pipeline installation is completed, open all valves and purge repeatedly to ensure that the pipeline is clean and free of residual impurities
It is recommended to use dry nitrogen or compressed air for pressure tests. It is strictly forbidden to use a low-temperature medium after a hydrostatic test.